ECO VOLT NEO 1100VA/12V:
- Capacity- 1100VA, Maximum bulb load- 924W
- Technology- Sine Wave Technology
- No of battery supported- One Battery (12V)
- LVFC technology (Low voltage Fast Charging charging) ensures full battery charging current for input voltage greater than 95V
- Adaptive battery charging control (ABCC) ensures longer battery life & higher backup time
- User friendly LED indication for checking performance of inverter battery system
- UPS Mode, output voltage is kept in range of 180V to 260V – ensuring safety of sensitive appliances such as computers. In Eco Mode, voltage range is extended thereby reducing battery usage.
- Advanced Micro processor design ensures reliable & quick switchover from mains to inverter & vice versa (less than 15 Ms)
- Higher battery charging current ensures faster battery recharge enabling optimum battery capacity during next power cut
- Equipped with over charging, overload, short circuit & over temperature protections & low battery, switch over, overload alarm
- Supports all battery types Tubular, SMF Flat plate & local (80Ah – 250Ah)
Features & Benefits:
Battery Dimensions
Technical Specifications:
Models | 1100VA | 12V | |
UPS mode | ||
Input | Rated voltage | 230V AC |
Undervoltage Cut Off | 180+5V | |
Undervoltage Restoration | 190±5V | |
Overvoltage Cut Off | 265+5V | |
Overvoltage Restoration | 255+5V | |
ECO mode | ||
Undervoltage Cut Off | 85±10V | |
Undervoltage Restoration | 105±10V | |
Overvoltage Cut Off | 285±10V | |
Overvoltage Restoration | 275±10V | |
Output | Rated voltage (Normal Mode) | (200-220)V AC ± 5% |
Rated voltage (Turbo Mode) | (200-240)V AC ± 5% | |
Voltage (Mains Mode) | Same as input | |
Frequency (UPS/ECO Mode) | 50 ± 0.5Hz | |
Load Performance Factor | 0.6 to 0.8* | |
Frequency (Mains Mode) | Same as input (45-55 Hz) | |
Overload | > 105% | |
Transfer Time(UPS Mode) | < 20 ms. | |
Battery | Type/Voltage | 80Ah-200Ah - Tubular, Flat, SMF or Local Battery/ 12V |
Number | 1 | |
Typical Recharge Time | 10-12 Hrs. | |
Protection | Low Battery, Reverse Polarity | |
LED Displays | Power Switch ON (SYSTEM ON Mode) | System ON LED Indication (As per mode selection)Â |
Turbo | TURBO indication LED OFF/ON (As per mode selection on battery mode only) | |
Low Battery Pre-Alarm | LOW BATTERY LED will blink along with indication LED for SYSTEM ON Mode depending upon mode of selection | |
Low Battery (B/L) | LOW BATTERY + SYSTEM ON (As per mode selection) Indication Steady | |
ON Mains | ON MAINS + SYSTEM ON (As per mode selection) Indication Steady | |
Charging ON (CHG.) | ON MAINS + CHARGING + SYSTEM ON (As per mode selection) Indication Steady | |
Overload (O/L) | OVERLOAD + SYSTEM ON (As per mode selection) Indication Steady | |
DC Over Voltage | Battery Low + SYSTEM ON Blinking | |
Over Temperature | All LED Blinking | |
Mains Fuse Failure | Mains LED blinking + SYSTEM ON (As per mode selection) | |
Alarms | Mains to UPS change over | Single Beep for 1 Seconds |
Low Battery Pre-alarm | Beep with 1 second gap till Battery Low | |
Low Battery | Continuous beep for 10 Seconds | |
Overload & Short circuit | Continuous beep for 10 Seconds | |
Overload Pre-alarm | Beep with 1 second gap till Overload | |
Over temperature | Continuous beep till fault get reset | |
Input Fuse Failure | Continuous beep till fault get reset | |
Environmental | Operating Temperature | 0-45°C (32-113°F) |
Storage Temperature | 0-45°C (32-113°F) | |
Humidity | 0-95% RH non-condensing |