Product |
Solar NXG +1500VA |
INPUT |
Battery voltage |
24V |
Solar panel |
24V /1000Wp with Voc 36V-45V |
ECO MODE |
Mains high cut |
290V±10V |
Mains high cut recovery |
280V±10V |
Mains low cut |
100V±10V |
Mains low cut recovery |
110V±10V |
UPS MODE |
Mains high cut |
265V±10V |
Mains high cut recovery |
255V±10V |
Mains low cut |
180V±10V |
Mains low cut recovery |
190V±10V |
OUTPUT |
No load output |
220V±5V |
Output frequency |
50Hz±0.5Hz |
Load Performance Factor |
0.6to 0.8* |
Output wave form |
SINE WAVE |
Overload Handling |
110%FOR 30SECONDS |
150%FOR 2SECONDS |
200%FOR 1SECOND |
Protections |
Short Circuit ,Overload ,High Temperature |
FRONT PANEL DISPLAY INDICATIONS |
Switch on indication |
Switch LED ON |
ON Batt .indication |
ON Batt .LED Steady |
Low battery pre alarm indication |
ON Batt .LED Steady +Batt .Low LED Blinking |
Mains ON indication |
ON Mains LED steady |
Battery charging through mains |
ON Mains LED steady +Mains CHG .LED steady |
Battery charging through Mains + Solar |
ON Mains LED steady +Mains CHG .LED steady +Solar CHG .LED blinking /steady |
Battery charging through Solar only |
Solar CHG .LED blinking +Mains CHG .LED OFF |
Battery charged & Solar + Mains available |
ON Mains LED ON +Mains CHG .LED OFF +Solar CHG .LED blink |
Overload pre -alarm indication in UPS mode |
ON Batt .+Overload LED slow blinking |
Overload shutdown indication in UPS mode |
Overload LED steady |
Short circuit indication in UPS mode |
Overload LED fast blinking |
Mains power saving mode |
ON Mains (depends on the availability of Mains) + Power Saver LED ON + ON Batt .LED ON + Solar CHG .LED |
ECO mode selection |
ECO LED ON |
UPS mode selection |
ECO LED OFF |
BUZZER SOUND INDICATIONS |
ON battery |
2beep approx 1sec .interval |
Low battery pre -alarm |
10beeps |
Battery low shut down |
5sec .continuous ON |
Overload pre -alarm indication |
10beeps |
Overload shutdown indication |
5sec .continuous ON |
Short circuit |
5sec .continuous ON |
ECO /UPS Selection |
2seconds of continuous press (2beeps ) |
USER SELECTABLE SWITCHES |
Mains charging current selection switch |
10A(I -CHG .OFF )/15A(I -CHG .ON ) |
Battery type selection switch |
Tubular /Flat Plate /Gel -VRLA |
Mains input window selection switch |
ECO (100V-290V)/UPS (180V-260V) |
PHYSICAL |
Net weight (kg .) |
15.66Kg . |
Gross weight (kg .) |
16.90Kg . |
Dimensions (LxWxH )(mm ) |
375x315x150 |
ENVIRONMENTAL |
Operating temperature |
0-45°C (32-104°F ) |
Humidity |
0-95%RH non -condensing |
Reviews